Meet BT DEFENDER – Fast, Cool & Reliable.
| Type | DTH22b | DTH40 | |||||
|---|---|---|---|---|---|---|---|
| Title Rating | Adjustment Range | Adjustment Range | |||||
| Min | medium | max | Min | medium | max | ||
| Rating Current(A) | 0.14 | 0.1 | 0.14 | 0.16 | |||
| 0.21 | 0.16 | 0.21 | 0.25 | ||||
| 0.33 | 0.25 | 0.33 | 0 | ||||
| 0.52 | 0.4 | 0.52 | 0.63 | ||||
| 0.82 | 0.63 | 0.82 | 1 | ||||
| 1.3 | 1 | 1.3 | 1.6 | ||||
| 2.1 | 1.6 | 2.1 | 2.5 | ||||
| 3.3 | 2.5 | 3.3 | 4 | ||||
| 5 | 4 | 5 | 6 | 4 | 5 | 6 | |
| 6.5 | 5 | 6.5 | 8 | 5 | 6.5 | 8 | |
| 7.5 | 6 | 7.5 | 9 | 6 | 7.5 | 9 | |
| 8.5 | 7 | 8.5 | 10 | 7 | 8.5 | 10 | |
| 11 | 9 | 11 | 13 | 9 | 11 | 13 | |
| 15 | 12 | 15 | 18 | 12 | 55 | 18 | |
| 19 | 16 | 19 | 22 | 16 | 19 | 22 | |
| 22 | 18 | 22 | 26 | ||||
| 30 | 24 | 30 | 36 | ||||
| 34 | 28 | 34 | 40 | ||||
| 42 | 34 | 42 | 50 | ||||
| 55 | |||||||
| 56 | |||||||
| 65 | |||||||
| 67 | |||||||
| 74 | |||||||
| 80 | |||||||
| 110 | |||||||
| 130 | |||||||
| 155 | |||||||
| 200 | |||||||
| Number of Elements | 2 Elements | Standard | Standard | ||||
| 3 Elements | Semi-standard | Semi-standard | |||||
| Auxiliary Contact | 1a1b | 1a1b | |||||
| Return method | Manual/automatic | Manual/automatic | |||||
| Power Consumption(Note 1) | 1.8VA/pole | 2.0VA/pole | |||||
| Single Installation Unit | DZ22b | DZ40 | |||||
| Application Model | 3-element | Dtd22b/3 | Dtd40/30 | ||||
| Phase protection type | DTK22b | DTK40 | |||||
| Single type | DTZ22b | DTZ40 | |||||
| Combinable Electronic Controller | DMC9b,12,12b,18b,22b | DMC32b,40b,48b | |||||
| Combined Electronic Switch | DMC9b,12,12b,18b,22b | DMC32b,40b,48b | |||||
| External Size | 43 * 72 * 90.5 | 54 * 75.5 * 92 | |||||
| Acquisition Standard | Korean Register of Shipping | Korean Register of Shipping | |||||
| Download PDF Download DWG | Download PDF Download DWG | ||||||
| Type | DTH85 | DTH220 | |||||
|---|---|---|---|---|---|---|---|
| Title Rating | Adjustment Range | Adjustment Range | |||||
| Min | medium | max | Min | medium | max | ||
| Rating Current(A) | 0.14 | ||||||
| 0.21 | |||||||
| 0.33 | |||||||
| 0.52 | |||||||
| 0.82 | |||||||
| 1.3 | |||||||
| 2.1 | |||||||
| 3.3 | |||||||
| 5 | |||||||
| 6.5 | |||||||
| 7.5 | |||||||
| 8.5 | 7 | 8.5 | 10 | ||||
| 11 | 9 | 11 | 13 | ||||
| 15 | 12 | 15 | 18 | ||||
| 19 | 16 | 19 | 22 | ||||
| 22 | 18 | 22 | 26 | ||||
| 30 | 24 | 30 | 36 | ||||
| 34 | 28 | 34 | 40 | ||||
| 42 | 34 | 42 | 50 | ||||
| 55 | 45 | 55 | 65 | ||||
| 56 | |||||||
| 65 | 54 | 65 | 75 | ||||
| 67 | |||||||
| 74 | 63 | 74 | 85 | ||||
| 80 | 65 | 80 | 100 | ||||
| 110 | 85 | 107 | 125 | ||||
| 130 | 100 | 130 | 160 | ||||
| 155 | 120 | 150 | 180 | ||||
| 200 | 160 | 200 | 240 | ||||
| Number of Elements | 2 Elements | Standard | Standard | ||||
| 3 Elements | Semi-standard | Semi-standard | |||||
| Auxiliary Contact | 1a1b | 1a1b | |||||
| Return method | Manual/automatic | Manual/automatic | |||||
| Power Consumption(Note 1) | 3.5VA/pole | 2.3VA/pole | |||||
| Single Installation Unit | - | Dtd220/3 | |||||
| Application Model | 3-element | Dtd85/3 | DTK220 | ||||
| Phase protection type | DTK85 | - | |||||
| Single type | - | - | |||||
| Combinable Electronic Controller | DMC50,65,75,85 | DMC220 | |||||
| Combined Electronic Switch | DMC50,65,75,85 | DMC220 | |||||
| External Size | 70 * 87 * 102.5 | 154 * 114 * 180 | |||||
| Acquisition Standard | |||||||
| Download PDF Download DWG | Download PDF Download DWG | ||||||
| Type | HRD150 | HRD180 | |||||
|---|---|---|---|---|---|---|---|
| Title Rating | Adjustment Range | Adjustment Range | |||||
| Min | medium | max | Min | medium | max | ||
| Rating Current(A) | 0.14 | ||||||
| 0.21 | |||||||
| 0.33 | |||||||
| 0.52 | |||||||
| 0.82 | |||||||
| 1.3 | |||||||
| 2.1 | |||||||
| 3.3 | |||||||
| 5 | |||||||
| 6.5 | |||||||
| 7.5 | |||||||
| 8.5 | |||||||
| 11 | |||||||
| 15 | |||||||
| 19 | |||||||
| 22 | |||||||
| 30 | |||||||
| 34 | |||||||
| 42 | 34 | 42 | 50 | ||||
| 55 | |||||||
| 56 | 45 | 56 | 67 | ||||
| 65 | |||||||
| 67 | 54 | 67 | 80 | ||||
| 74 | |||||||
| 80 | 65 | 80 | 95 | 65 | 80 | 95 | |
| 110 | 90 | 110 | 130 | 90 | 110 | 130 | |
| 130 | 105 | 130 | 155 | 105 | 130 | 155 | |
| 155 | 125 | 155 | 185 | ||||
| 200 | |||||||
| Number of Elements | 2 Elements | Standard | Standard | ||||
| 3 Elements | Semi-standard | Semi-standard | |||||
| Auxiliary Contact | 1c | 1c | |||||
| Return method | Manual | Manual | |||||
| Power Consumption(Note 1) | 2.3VA/pole | 2.3VA/pole | |||||
| Single Installation Unit | - | - | |||||
| Application Model | 3-element | HRD150/3 | HRD180/3 | ||||
| Phase protection type | - | - | |||||
| Single type | - | - | |||||
| Combinable Electronic Controller | DMC100,125,150C | DMC150,180 | |||||
| Combined Electronic Switch | DMC100,125,150C | DMC150,180 | |||||
| External Size | 124 * 60 * 97 | 129 * 84 * 97 | |||||
| Acquisition Standard | |||||||
| Download PDF Download DWG | Download PDF Download DWG | ||||||